Properties
Main applications
Technical data
Mechanical | Tolerance | |
Diameter | 3 mm | +/- 0.1 mm |
Length L | 168 mm | +/- 1 mm |
Luminous length LL | > 148 mm | +/- 1 mm |
Length of electrodes | > 10 mm | + 15 mm |
Warm-up time | 3 min | - |
Working temperature | 0 bis + 50°C | - |
Storing temperature | - 50 bis + 110°C | - |
Electrical | ||
Working voltage | 395 VRMS | +/- 50 VRMS |
Working current | 5 mARMS | + 1 mARMS |
Power consumption | 1975 mVA | +/- 10 % |
Sinusoidal AC | 20 - 100 KHz | - |
Optical | ||
Colour temperature | 7800°K | +/- 200°K |
Visible colour | weiss | - |
Luminance | 28000 cd/m2 | +/- 5% |
Lifetime | 20000 h | - |
CCFLs are made of glass, which is easily broken. The exchange of CCFL tubes and inverters requires certain technical skills. Our safety and handling instructions for inverters and CCFLs keep you up-to-date. We kindly ask you to read this instructions carefully, which can be found in the area: Information. Silicone cables and and silicone caps of the originally built-in CCFL can be re-used if in a good condition. If not re-usable we offer silicone replacement cables and caps and other hard to find parts in the area: CCFL -> Accessories. As a replacement for
Additional notes
Cold Cathod Fluorescent Lamp 125mm x 2.2mm (L x Ø), type longlife, white, 7800°K
Cold Cathod Fluorescent Lamp 128mm + 98mm x 2.6mm (L-dimensions x Ø), type standard, white, 7800°K, L-shape, for TFT Kyocera KCS057Q1AJ
White silicone cap in rectangular shape for CCFLs between 2mm and 2.3mm diameter
This Product was added to our catalogue on 10/08/2012.